PRODUCT SPECIFICATIONS

GASOLINE
CAPACITY
AND TYPE:

3£fl/''i-ONS j

UNLEADED

REGULAR

OILTYPE

(API-SF-SJ):

SAE 30 (ABOVE 32° F)
SAE 5W-30
(BELOW 32°F)

OIL CAPACITY:

3.0 PINTS

SPARK PLUG:
(GAP: .030")

CHAMPION RJ19LM
OR J19LM

GROUND SPEED FORWARD:

(MPH):

1

ST

1.2

2ND

1.5

3RD

2.4

4

TH

3.5

5

TH

4.8

6

TH

5.3

REVERSE: 1.5

TIRE PRESSURE: FRONT: 14PSI

REAR: 10PSI

CHARGING

3AMPS BATTERY

SYSTEM:

5 AMPS HEADLIGHTS

BATTERY:

AMP/HR: 28

MIN. CCA: 230
CASE SIZE: U1R

BLADE BOLT

TORQUE:

27-35 FT. LBS.

CONGRATULATIONS on your purchase
of a new tractor. It has been designed,
engineered and manufactured to give you
the best possible dependability and
performance.

Should you experience any problem you

cannot easily rtfftedy, pleqiS« contact a

t+K-tf iaii.ilifie 'i-stivice center.

We have competent, well-trained techni­
cians and the proper tools to service or

repair this tractor.
Please read and retain this manual. The

instructions will enable you to assemble
and maintain your tractor properly.
Always observe the “SAFETY RULES”.

REPAIR AGREEMENT

A Repair Agreement is available on this
product. Contact your nearest Sears store
for details.

CUSTOMER RESPONSIBILITIES

• Read and observe the safety rules.
• Follow a regular schedule in maintain­

ing, caring for and using your tractor.

• Follow the instructions under “Mainte­

nance” and “Storage” sections of this
owner’s manual.

A

w

ARNING: This tractor is equipped

with an internal combustion engine and
should not be used on or near any
unimproved forest-covered, brush-
covered or grass-covered land unless the
engine’s exhaust system is equipped with
a spark arrester meeting applicable local
or state laws (if any). If a spark arrester is

used, it should be maintained in effective

working order by the operator.

In the state of California the above is
required by law (Section 4442 of the
California Public Resources Code).. Other

states may have similar laws. Federal

laws apply on federal lands. A spark
arrester for the muffler is available

through your nearest Sears service center

(See REPAIR PARTS section of this
manual).