Location Requirements

You will need

A location that allows for proper exhaust installation. See
“Venting Requirements.”

A 120-volt, 60-Hz., AC-only, 15- or 20-amp circuit.

A grounded electrical outlet located within 2 ft (610 mm) of either
side of the dryer. See “Electrical Requirements.”

A sturdy floor to support the dryer weight (dryer and load) of

115 lbs (52 kg). The combined weight of a companion appliance
should also be considered.

A level floor with a maximum slope of 1" (25 mm) under entire
dryer.

Do not operate your dryer at temperatures below 45ºF (7ºC). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.

The dryer must not be installed or stored in an area where it will be
exposed to water and/or weather.

Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.

Installation Clearances

The location must be large enough to allow the dryer door to open
fully.

23

7

8

(606 mm)

"

20

3

4

(527 mm)

"

31"

(787 mm)

*

Dryer Dimensions

†Height with caster is 32½" (826 mm)

*Most installations require a minimum 5" (127 mm) clearance

behind the dryer for the exhaust vent with elbows. See “Venting
Requirements.”

Minimum spacing for recessed area and closet installation

The following dimensions shown are for the minimum spacing
allowed when the dryer is to be operated with, or without, the Stack
Stand Kit. To purchase a Stack Stand Kit, see “Assistance or
Service.”

Additional spacing should be considered for ease of installation
and servicing.

Additional clearances might be required for wall, door, and floor
moldings.

Additional spacing of 1" (25 mm) on all sides of the dryer is
recommended to reduce noise transfer.

For closet installation with a door, minimum ventilation openings
in the top and bottom of the door are required. Louvered doors
with equivalent ventilation openings are acceptable.

Companion appliance spacing should also be considered.

Recessed or closet installation - Dryer only

A. Side view - closet or confined area
B. Recessed area

A

B

3"*
(76 mm)

14"*
(356 mm)

18"* (457 mm)

1"
(25 mm)

1"
(25 mm)

Recessed or closet installation - Stacked

A. Recessed area
B. Side view - closet or confined area

C. Closet door with vents

DRYER

WASHER

(76 mm)

3"*

(305 mm)

12"*

(305 mm)

12"*

1"

(25 mm)

1"

(25 mm)

A

B

C

1"*

(25 mm)

3"*

(76 mm)

48 in. *

2

(309.7 cm )

2

24 in. *

2

(154.8 cm )

2

3"*

(76 mm)

Mobile Home - Additional Location Requirements

This dryer is suitable for mobile home installations. The installation
must conform to the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for
Mobile Home Construction and Safety, Title 245, HUD Part 280) or
Standard CAN/CSA-Z240 MH.

Advertising