Electrical Safety

OBSERVE ALL LOCAL CODES AND ORDINANCES.

DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER SUPPLY CORD GROUND PRONG.

ELECTRICAL GROUND IS REQUIRED ON THIS APPLIANCE.

A 115-volt 60 Hz, AC only, 15A fused and properly grounded electrical supply is required. A time

delay fuse or time delay circuit breaker is recommended. Use a dedicated circuit, serving only this

appliance.

DO NOT USE AN EXTENSION CORD.

RECOMMENDED GROUNDING METHOD

For your personal safety, this appliance must be grounded. This appliance has a power supply

cord with a 3-prong grounding plug. To minimize possible shock hazard, the cord must be plugged

Into a mating grounding type wall receptacle and grounded In accordance with the National
Electrical Code (ANSI/NFPA 70) latest edition and all local codes and ordinances. If a mating wall

receptacle Is not available. It Is the personal responsibility and obligation of the customer to have
a properly grounded 3-prong wall receptacle installed by a qualified electrician.

115V-

w

230V-

Power cord may include a current interrupter

device. A test and reset button is provided on the

plug case. The device should be tested on a
periodic basis by first pressing the TEST button
and then the RESET button. If the TEST button

does not trip or if the RESET button will not stay

engaged, discontinue use of the air conditioner and
contact a qualified service technician.

NOTE;

The shape may be different according to its model.

Use Wall Receptacle

Power Supply

^

^ Standard 125V,

i \

1 j 3-wire grounding

V

0

y receptacle rated

------- 15A, 125VAC

Use 15 AMP. time

delay fuse or 15 AMP.
circuit breaker.

^

X standard 250V,

f

" " ^ 3-wire grounding

1 A y receptacle rated

15A.250VAC

X standard 250V,

/ 1 3-wire grounding
1 _ y receptacle rated

20A,250VAC

Use 20 AMP. time

delay fuse or 20 AMP.
circuit breaker.

Electrical Shock Hazard
Plug Into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result
in death, fire, or eiectrical shock.