9

4

CONTINUED

3H

Once the return panel (16c) has been adjusted,

secure the expander (16a) to the wall jamb (15)

by way of a clamp so as to keep the return panel

level (16c).

Ensure that the return panel (16c) is vertical by way

of a level. If there need be a correction, adjust the

verticality of the expander (16a) in relation to the

wall jamb (15).

3I

By way of #8- 3/8 screws (26), as well as screw

caps (27), permanently secure the wall jamb (15)

to the expander (16a).

3J

15

16a

16c

3H

3I

3J

15

27

26

15

16a

16c