INSTALLATION INSTRUCTIONS:

VENTING YOUR OVEN:

1. The purpose of ventilation hoods is to

direct and capture smoke, grease-laden
vapors, heat, odors, or fumes.


2. Low temperature equipment (maximum

temperature 250°F/121°C) does not
produce heat, odors, fumes, grease laden
vapors or smoke and is not required to
be vented.

3. Most jurisdictions consider our low-

temperature ovens (maximum
temperature is 350°F/177°C) as low-heat
appliances not requiring vent hoods.

4. Installation must conform to local codes.

The authority having jurisdiction of
enforcement of the codes will have the
responsibility for making interpretations
of the rules.



ELECTRICAL SPECIFICATIONS:

Model Nos.

Volts

Watts

Amps

Hertz

Ph

NEMA

CO-151-XUA-5B-1201 120

1920

16.6

60

1 5-20P

CO-151-X-185B-1201 120

1920

16.6

60

1

5-20P

All models are designed for AC Service.

Model numbers may have the letters: L, M, T, or S.


HOW TO INSTALL CABINETS:

1. Remove all packing material from inside

and outside of cabinet.

2. Position cabinet on level floor; install the

cabinet interior (pan slides) if not
already installed.

3. Plug power cord into proper wall

receptacle.


NOTES: Cold food is NOT to be added when
unit is operating in HOLD mode.

For HOLD mode, preheat unit to 180°F/82°C
for 60 minutes.




To install stacking units, refer to instruction sheet FL-2211, STACKING INSTALLATION.