AC Power Draw and Thermal Dissipation:

Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.
Typical line impedance used.
Measurements made with 120VAC mains. Line current figures for 230VAC units derived by multiplying 120VAC figures by 0.5.
Data based on all channels driven.

watts in

watts out

dissapated

Btu/hr

kcal/hr

At Idle

60

0

60

205

52

1/8th Power Pink Noise

8 Ohms/Ch.

300x2

Typical of program material

16 Ohms Bridge

600

just at clip.

4 Ohms/Ch.

300x2

8 Ohms Bridge

600

2 Ohms/Ch.

150x2

4 Ohms Bridge

300

70V/Ch.

300x2

140/200V Bridge

600

1/3rd Power Pink Noise

8 Ohms/Ch.

300x2

Typical of program material

16 Ohms Bridge

600

with severe clipping.

4 Ohms/Ch.

300x2

8 Ohms Bridge

600

2 Ohms/Ch.

150x2

4 Ohms Bridge

300

70V/Ch.

300x2

140/200V Bridge

600

444

657

742

275

1760

2608

2942

1091

516

764

862

320

200

204

102

207

716

968

964

527

4.3

5.6

5.4

3.3

8.6

11.3

10.8

6.5

330

477

469

225

1307

1890

1859

892

383

554

545

261

78

78

38

75

461

631

583

336

2.9

3.7

3.5

2.1

5.8

7.4

7.0

4.2

CTs 600

Watts

Thermal Dissipation

Line Current

230VAC

Line Current

120VAC

Rated

Power

Load

8 AC Power Draw and Thermal Dissipation

Advertising