4

a. Please connect the G & DO pin to the external relay (buzzer) device

When no event happens, DO output is 5V (DO and GND are disconnected). When the camera

detects event happening and triggers external alarm, DO output is 0V (DO and GND are

connected).

b. Please connect the G & DI pin to the external trigger device.

If you select "N.O" in "Input sensor setting", when external devise or circuit makes DI and GND

pin connected, the camera input alarm is triggered, and then camera will execute the action

user has set, for example, send snapshot to E-mail address.

If you select "N.C" in "Input sensor setting", when external devise or circuit makes DI and GND

pin disconnected, the camera input alarm is triggered, and then camera will execute the action

user has set, for example, send snapshot to E-mail address.

Advertising