Salter Brecknell ES2500 User Manual

Es2500, Quick user guide, Equestrian scale

Advertising
background image

ES2500

Equestrian Scale

Quick User Guide

CODE

MODE

MEANING / POSSIBLE SOLUTION

– – – – – –

Normal Operating Mode

Gross Overload. A weight greater than the rated

capacity has been applied to the scale. Remove the

weight from the platter or try re-calibrating the scale.

Otherwise, check for a bad load cell connection or

possible load cell damage due to overloading.

Normal Operating Mode

Indicates that the battery voltage is too low for nor-

mal operation. Re-charge the battery.

Err 3

All Modes

Non-volatile memory read error. One or more setup

parameters have been lost.

Err 4

All Modes

Non-volatile memory write error. Indicator needs

service.

Err 7

Initialization

No reading from the ADC. Make sure there is a load

cell(s) connected to the indicator at start-up.

Err 9

Normal Operating Mode

Span calibration value has been lost. Re-calibrate

the scale.

F1

In configuration mode

Toggle switch on rear of indicator set to configuration

mode, toggle switch to left to return back to normal

weight mode Or check to see if the toggle switch

loom is still connected to main PCB inside indicator.

Display Error Codes

Electromagnetic Compatibility Statement for North America

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant

to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful

interference when the equipment is operated in a residential installation. This equipment generates, uses

and can radiate radio frequency energy and if not installed and used in accordance with the instruction

manual, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this

equipment does cause harmful interference to radio or television reception which can be determined

by turning the equipment off and on, the user is encouraged to try to correct the interference by one of

the following measures:

Re-orient or relocate the receiving antenna.

Increase the separation between the equipment and the receiver.

Connect the equipment to an outlet different from that to which the receiver is connected.

Consult the dealer or an experienced radio / TV technician for help.

Salter Brecknell Weighing Products

1000 Armstrong Dr.

Fairmont, MN 56031

Toll free: 800-637-0529

Tel: 507-238-8702 Fax: 507-238-8271

e-mail: [email protected]

www.salterbrecknell.com

12/04 es2500_g.indd PN 43067-0018 e1

Advertising