Salter Brecknell RD-65 Remote Display User Manual
Page 7
5
<LF> Line Feed character (0ahex)
3.1.8 Data format example: 123123kg, SMA transmit data
<LF><SP><SP><G><SP><SP><-><1><2><3><1><2><3><kg><SP><CR>
Notes for symbols used in commands and response:
<LF> Line Feed character (0ahex)
<SP> Space (20hex)
<G/N> G = Gross, N = Net
<kg/lb> lb = lb, kg = kg
<CR> Carriage Return character (0dhex)
3.1.9 Data format example: 123.233lb, transmit data format of SB-400
<SP><1><2><3><.><2><3><3><lb><G><SP><SP><CR>
Notes for symbols used in commands and response:
<SP> Space (20hex)
<kg/lb>lb = lb,kg = kg
<G/N> G = Gross, N = Net
<CR> Carriage Return character (0dhex)
3.1.10 Data format example: 233233lb, transmit data format of SB-200
<CR><SP><SP><2><3><3><2><3><3><SP><lb><G><ETX>
Notes for symbols used in commands and response:
<CR> Carriage Return character (0dhex)
<SP> Space (20hex)
<kg/lb>lb = lb,kg = kg
<G/N> G = Gross, N = Net
<ETX> end of text. (03hex)
3.1.11 Data format example: 233233lb, transmit data format of IQ355
<STX><SP><SP><2><3><3><2><3><3><L><G><SP><CR><LF>
Notes for symbols used in commands and response:
<STX> Start of Text ( 02hex)
<SP> Space (20hex)
<L/K>L = lb,K = kg
<G/N> G = Gross, N = Net
<CR> Carriage Return character (0dhex)