3.

Automatic setup – RS-485

RD-4 remote display, apply the jumpers to JP3 and JP4, leave JP1, JP2 and JP5 open.

RD-2 remote display – apply jumpers to JP3, JP4, and JP5. Leave JP1, JP2 and JP6 open.

Connect the cable as shown below to J3.

Power down the RD Series Remote Display. Remove the two screws holding the setup switch

cover located on the center of the back cover. Slide the switch to the left position for setup. Power

up the RD Series Remote Display. Power up your digital indicator. The RD Series Remote

Display will begin cycling through the possible combinations of baud rate, bits and parity. When

the configuration from your indicator is found, the RD Series Remote Display will show SET and

begin to operate. Slide the configuration switch to the right position and replace the cover and two

screws. Attach the rear cover.

RD-4- 4” remote RS485 connections

RD-4- 2” remote RS485 connections