When the cooling unit is plugged in and receiving electrical power the top arrow will be lit. This top arrow will blink
when the compressor is operating and the unit is cooling. The middle arrow is lit when the programming is being
changed. The bottom arrow is lit when the cellar's temperature exceeds the alarm set temperature. Also at this point
the red alarm light will be on.

BOTTLE PROBE

(OPTIONAL)

Allow the enclosure to stabilize at the desired temperature for several days. Fill a suitable bottle with wine (preferably)
or water, insert the bottle probe into the bottle, and place it in the enclosure. Do not connect the probe to the unit until
the bottle has had sufficient time to cool to the enclosure temperature (several days). Connect the probe to the outlet
located on the front face of the unit. The on and off operation of the unit is now controlled by the temperature of the
wine in the bottle. The temperature displayed is that of the bottle. Unplugging the probe will return control of the unit to
the room air temperature.

PROGRAMMING THE SENTINEL II

In order to set the DESIRED TEMPERATURE OF THE WINE CELLAR, the cooling unit must be installed as per
previous instructions. The current temperature will appear on the display and control panel. Press the two panel
buttons at the same time once and release. The panel will show the word "set", followed by "cool". After a few
seconds the panel will automatically show the set temperature previously programmed.

To change to your desired wine cellar
temperature press either of the panel
buttons until the desired temperature is
shown. If the desired temperature is the

only parameter you wish to change press the two panel buttons simultaneously three more times until the panel shows
the word "done" however to continue in the program mode press the panel buttons simultaneously once more. Now
you can change the EVAPORATOR FAN OPERATION.

The panel will show the word "fan" for a
few seconds and then change
automatically to the current fan setting,
either "auto" or "on". To change the

current setting press either panel button once. The new setting should now appear. If you do not wish to change any
other parameters press the panel buttons simultaneously twice until the panel shows the word "done", however to
continue in the program mode press the panel buttons simultaneously once more. Now you can set the ALARM
TEMPERATURE.

To change the current setting press either panel button until the
desired alarm temperature is reached. To complete the program
operation press the panel buttons simultaneously once. The panel
should show the word "done". Your changes have now been

recorded by the Sentinel II. If the word "done" does not appear at the end of the programming mode the changes will
not be saved.