Specifications, Transducer range and display resolutions – CDI Torque TORQUE AND ANGLE Electronic Torque Wrench User Manual

Page 6

Advertising
background image

sPEcIFIcATIONs

DISPLAY
LCD on swivel neck

DISPLAY SPECIFICATIONS
Size: 4.7 inch
Resolution: 480 (RGB) X 272

ACCURACY
±0.5% of indicated test value from 10% to 100% of
rated capacity

UNITS OF MEASUREMENT
ft.lb., in.lb., in.oz., kgcm, Nm and cNm

Operating Temperature
0 - 50°C (32 - 122°F)

STORAGE
-20 - 70°C (-4 - 158°F)

DIMENSIONS
Width: 10.0”
Height: 15.2”
Depth: 2.5”

WEIGHT
11 lbs

BATTERY
Six 1 .5V (AA), replaceable

AC ADAPTER
Input: 100 24OVAC (50-60 Hz)
Output: 9VDC, 1 .66A

INTEGRAL TRANSDUCER
Full bridge strain gage,
350 ohms, 1500 µE, 3mV/V F.S., 3.3V excitation

TRANsDUcER RANgE AND

DIsPLAY REsOLUTIONs

DTT built-in transducers provide industry standard
female square drives, and a full bridge strain gage
sensing element.

Contact your CDI Torque representative for service
and/or calibration.

IMPORTANT

Apply torque loads only. Never side-load a wrench
while installed on the tester transducer.

IMPORTANT

Transducers can withstand a torque of 25% over full
range. Do not use the tester if the transducer:
• Does not zero,
• Does not calibrate, or
• Has been over-torqued.

The table below describes minimum and maximum
display ranges.

Part

Square Units

Number

Drive

English

Metric


1001-O-DTT 1/4”

10.0-100.0 in.oz. 7.0-70.6 cNm

2001-O-DTT 1/4”

20.0-200.0 in.oz. 14.1-141.2 cNm

4001-O-DTT 1/4”

40.0-400.0 in.oz. 28.2-282.4 cNm

251-I-DTT

1/4”

2.5-25.0 in.lb.

2.8-28.25 dNm

501-I-DTT

1/4”

5.00-50.00 in.lb.

5.65-56.50 dNm

1001-I-OTT 1/4”

10.0-100.0 in.lb.

11.3-113.0 dNm

2502-I-DTT 3/8”

25.0-250.0 in.lb.

28.2-282.5 dNm

4002-I-DTT 3/8”

40.0-400.0 in.lb.

45.2-452.0 dNm

10002-I-DTT 3/8”

100-1000.0 in.lb. 113-1130 dNm

2503-F-DTT 1/2”

25.0-250.0 ft.lb.

33.9-339.0 Nm

6004-F-DTT 3/4”

60.0-600.0 ft.lb.

81.3-813.6 Nm

Advertising