Electric signal dial, Setting electric contact arm on single scale model – CDI Torque DIAL TORQUE WRENCH SINGLE SCALE User Manual

Page 3

Advertising
background image

BEZEL

ELECTRIC

CONTACT

ARM

PUSHER

NEEDLE

(ORANGE)

Before using all models of dial torque wrenches, it is
strongly suggested to cycle/operate them 3 times at
full scale in the torque direction in which they will be
used. Dial torque wrenches must always be

zeroed

before use. To set orange pusher & blue follower
needle for right-hand (CW) torquing:

1. Turn bezel in left-hand (CCW) direction until, blue
memory follower needle contacts orange pusher
needle.

2. Continue to turn bezel left-hand (CCW) until blue
memory follower needle is lined up with

zero (0) of

outer graduation on portion of dial for IN.LB., FT.LB.,
METRIC readings.

3. Apply force on the wrench handle until blue follower
needle reaches desired torque. When force is released
orange pusher needle will return to

zero and blue

memory follower needle will remain at torque applied.

4. For repetitive torque operations (once the

zero

has been set as instructed above), the blue memory
follower needle can be returned to

zero by use of the

follower needle knob. It is ready for the next operation.

5.

IMPORTANT - When using the memory feature

always make sure that the blue follower memory
needle is on

zero before torquing.

ELECTRIC sIgNAL dIAL

1. Turn bezel (CCW) until light and buzzer goes on.

2. Continue to turn bezel (CCW) until inner

zero of

desired scale (English or Metric) is lined up with
orange pusher needle.

3. Now turn bezel (CW) until light goes off and
orange pusher needle is aligned with desired torque
graduation in inner portion of scale orange pusher
needle is now preset to desired torque value.

4. Apply force to handle in the (CW) direction. When
the preset torque value is reached the light and
buzzer will go on. When force on the handle is
released orange pusher needle will return to the
preset torque value.

5. To change the preset torque value to another,
turn the bezel as required to the new torque value
within the same dial graduation and proceed as in
step 4 above.

6. For CCW torque reverse directions in steps 1
through 5.

7.

IMPORTANT - Always make sure that the electric

contact arm is

zeroed.

sETTINg ELECTRIC

CONTACT ARM

ON sINgLE sCALE MOdEL

BEZEL

MEMORY

FOLLOWER

NEEDLE

(BLUE)

PUSHER

NEEDLE

(ORANGE)

MEMORY

FOLLOWER

NEEDLE

KNOB

FOLLOWER NEEdLE dIAL

sETTINg MEMORY

FOLLOWER NEEdLE

ON sINgLE sCALE MOdEL

Advertising