HUMIDITY:

The factory preset for this setting is “3”.

If the humidity inside the cellar is too low, press the “Set”
button, then use the “Up” button until the desired setting is
reached. The recommended range for this setting is 0-6.

TEMPERATURE DIFFERENTIAL:

The factory preset for this

setting is “4”.

This setting determines the Temperature Differential and
therefore the temperature at which the cooling unit will
cycle on. The recommended range for this setting is 4 or 5.

HIGH TEMPERATURE ALARM:

The factory preset for this

setting is “70”.

This setting designates the High temperature inside the
cellar at which the alarm is triggered. We recommend
leaving this setting at the factory preset.

 

Advanced Operation

CellarPro cooling systems can be programmed with advanced settings to
achieve more control over conditions inside the cellar. Conditions like
humidity, the Temperature Differential, and alarm settings all can be
modified for custom applications. To access the advanced settings, do the
following:

Press the “Set” button and the “Down” button together at the same time, and

hold for three seconds. Then, use the “Up” or “Down” button to scroll to the
following screen:

LOW TEMPERATURE ALARM:

The factory preset for this

setting is “45”.

This setting designates the Low temperature inside the cellar
at which the alarm is triggered. We recommend leaving this
setting at the factory preset.

ENERGY SAVINGS MODE DIFFERENTIAL:

The factory preset

for this setting is “4”.
This setting controls the Temperature Differential for the
Energy Savings Mode. The recommended range for this
setting is 2-4.