Steady burn option, Warning! tricore® light head flash pattern, Tricore take down flash pattern – Code 3 SuperVisor with TriCore for Ford F150 User Manual

Page 6

Advertising
background image

6

Flash Patterns

STANDARD LIgHT HEAD FLASH PATTERNS

PATTERN NO PATTERN DESCRIPTION
1

FAST ALTERNATING QUAD FLASH 100ms/25ms

2

PICKET FENCE SINGLE FLASH 200ms/25ms

3

ALTERNATING SINGLE FLASH 200ms/25ms

4

PICKET FENCE QUAD FLASH 100ms/25ms

5

PICKET FENCE SIX FLASH 75ms/25ms

6

SLOW ALTERNATING QUAD FLASH 150ms/50ms

7

SLOW ALTERNATING SIX FLASH 125ms/25ms

8

FAST ALTERNATING SIX FLASH 75ms/25ms

9

VARIABLE RATE PICKET FENCE, SINGLE FLASH

10

ALTERNATING QUAD FLASH, 80 FPM, NFPA COMPLIANT

11

CYCLE FLASH

12

SIMULTANEOUS QUAD FLASH, 75 FPM, NFPA COMPLIANT

TAKE DOwN FLASH PATTERNS

PATTERN NUMBER

PATTERN DESCRIPTION

1

FAST QUAD 80FPM

2

SLOW QUAD 60FPM

3

FAST SINGLE 375FPM

4 FACTORY DEFAULT

MEDIUM SINGLE 115FPM

5

SLOW SINGLE 60FPM

6

FAST DOUBLE 115FPM

7

SLOW DOUBLE 60FPM

8

FAST SIX 80FPM

9

SLOW SIX 60FPM

10

VARIABLE RATE SINGLE

11

NFPA QUAD 75FPM

12

CYCLE FLASH

This Product contains high intensity TriCore® devices. To prevent eye

damage, DO NOT stare into light beam at close range.

wARNINg!

TriCore® Light Head Flash Pattern

To change the flash patterns of the TriCore Light Heads, activate the Light Bar in Level 1 (Blue Wire) and then momentarily

touch the Green (Pattern Select) wire to +power. Repeating this procedure allows the operator to cycle through the numerous

flash patterns offered until the desired pattern is achieved.

To reset the flash patterns to the factory default, activate the Light Bar in Level 1 (Blue Wire) and then hold the Green (Pattern

Select) wire to +power for approximately 4 seconds.

Steady Burn Option

The SuperVisor® can operate Light Head #2 (second Light Head from the driver side) in steady burn mode. To change the #2 Light

Head from flashing to steady burn, remove the mounting screws that attach the SuperVisor's Cover to the Outer Panel to gain

access to the printed circuit board inside (see the exploded view on page 7). Move the Shunt Option Jumper on the printed circuit

board to the "OPTION JP1" position as shown below. The #2 Light Head should now operate in steady burn. Carefully replace the

SuperVisor's Cover over the Outer Panel and replace the Cover Mounting Screws.

Note: Be extremely careful to replace the wiring such that you don't pinch a wire when you

replace the SuperVisor's Cover. Test the unit to be sure that it works properly.

<---------------"OPTION JP1" Jumper Position

TriCore Take Down Flash Pattern

Selecting Flash Patterns:

The Take Down Lights can be programmed to flash at different rates.

STEP 1:

Power-up the light bar. Select the Take Down Flash Mode (ORANGE) by applying +power. Programming will not work if

more than one function is selected at a time.

STEP 2:

Observe the flash pattern and determine which pattern is in operation (see Take Down Flash Patterns). This table shows

the available flash patterns. Once the flash pattern has been determined, proceed to Step 3. NOTE: The default flash pattern for

Take Down Lights is Medium Single 115FPM.

STEP 3:

Scroll to the next pattern by momentarily holding the GREEN wire to +power for approximately one (1) second. The light

bar will stop flashing when the wire is connected to +power. Release the wire and the next pattern as listed in the table below will

begin to flash. The new pattern is automatically stored each time.

Advertising