Bottom view (wiring label), Warning, Special wiring instructions – Code 3 TriCore NarrowStik Controller User Manual

Page 6: Front facing wiring of the narrowstik

Advertising
background image

6

Figure 3- Rear panel connections and wiring label located on

bottom of the control head.

Bottom View (wiring label)

Larger wires and tight connections will provide longer service life for components. For high current wires it

is highly recommended that terminal blocks or soldered connections be used with shrink tubing to protect

the connections. Do not use insulation displacement connectors (e.g. 3M

®

Scotchlock type connectors).

Route wiring using grommets and sealant when passing through compartment walls. Minimize the number

of splices to reduce voltage drop. High ambient temperatures (e.g. underhood) will significantly reduce the

current carrying capacity of wires, fuses, and circuit breakers. Use "SXL" type wire in engine compartment.

All wiring should conform to the minimum wire size and other recommendations of the manufacturer and

be protected from moving parts and hot surfaces. Looms, grommets, cable ties, and similar installation

hardware should be used to anchor and protect all wiring. Fuses or circuit breakers should be located

as close to the power takeoff points as possible and properly sized to protect the wiring and devices.

Particular attention should be paid to the location and method of making electrical connections and splices

to protect these points from corrosion and loss of conductivity. Ground terminations should only be made

to substantial chassis components, preferably directly to the vehicle battery. The user should install a

fuse sized to approximately 125% of the maximum Amp capacity in the supply line to protect against

short circuits. For example, a 30 Amp fuse should carry a maximum of 24 Amps. DO NOT USE 1/4"

DIAMETER GLASS FUSES AS THEY ARE NOT SUITABLE FOR CONTINUOUS DUTY IN SIZES ABOVE

15 AMPS. Circuit breakers are very sensitive to high temperatures and will "false trip" when mounted in hot

environments or operated close to their capacity.

wARNING!

Narrowstik™ / wingMan™ / LC-Stik / Large LED Narrowstik™ / Lightbar wire Designations

The manual for the Narrowstik (and other LED models) contains detailed information related to wiring and mounting of the Narrowstik

itself. Refer to figure 4, on page 7, for additional information on the function of each wire in the 10-wire and 11-wire cable and Nar-

rowstik.

Special wiring Instructions

Front facing wiring of the Narrowstik™

The standard wiring method is for a rear-facing, driver side cable exit system as shown in figure 4. If it is desired to mount the device

as a front-facing, or passenger side cable exit, system the LED control wires will have to be reversed as indicated. The connector

shown in figure 4 DOES NOT have the wires reversed. The connector shown has standard rear facing cable exit wiring.

Wiring for Narrowstik Models with outboard flashing modules:

If you want the modules in the outboard positions to alternate during any arrow pattern (LFT, CTR, RHT), set the End Flash slide

switch to the ENABLE position and program the unit for 5 or 6 head arrow patterns. There are no changes to how the NarrowStik is

wired to the control head.

P/N - T11709

REV. 0

ARTBOARD - XA11709

LED NARROWSTIK CONTROL HEAD (BOTTOM)

11/11/09

10 WIRE CABLE

LIGHT BAR

NARROWSTIK

CNTL

HEAD PWR

PROGRAM

(+12V SW) BACKLIGHT

(DIM) WHITE

EXTERNAL

FLASH

BROWN

ORANGE

VIOLET

TAN

GREEN

GRA

Y

YELLOW

BLUE

AUX. OUTPUT

(SUPPLIES GROUND)

+12V

- SEE INSTRUCTIONS FOR FURTHER INFORMATION.

- DO NOT SHORT OUTPUTS TO +12 V.

- DISCONNECT POWER BEFORE SERVICE.

16 GA. WIRE

MINIMUM

15 AMP FUSE

OR CIRCUIT

BREAKER

(user supplied)

REAR VIEW

- LED USE ONLY.

PROGRAMMING:

1. APPLY POWER TO CONTROL

HEAD.

2. PLACE SLIDE SWITCH INTO

DESIRED FUNCTION.

3. TOUCH PROGRAM INPUT TO

GROUND MOMENTARILY AND

RELEASE. REPEAT UNTIL

DESIRED PATTERN IS SELECTED.

4. PROCEED TO NEXT FUNCTION IF

DESIRED.

TO RESTORE FACTORY DEFAULT,

HOLD PROGRAM INPUT TO

GROUND FOR 5 SECONDS.

RED/WHITE
RED

USER SUPPLIED

SWITCH

BLU

YEL

GRY

GRN

TAN

VIO

ORG

BRN

LIGHT HEAD

POWER

BLU

YEL

GRY

GRN

TAN

VIO

ORG BRN

T11709

3A

MAX.

3A FUSE

GND

GROUND

16 GA. MIN.

CONNECT

TO BATTERY

NEGATIVE (-)

(SEE MANUAL

FOR DET

AILS)

WARNING

END FLASH

ENABLE

DISABLE

DIM CONTROL

STEADY

PWM

AUXILIARY

DEVICE

3A MAX.

NEG. POS.

BATTERY