Code 3 Ultra-Lite Strobe Beacon Galls User Manual

U lt r a - l i t e

Advertising
background image

1

INSTALLATION INSTRUCTIONS

DC Models Only

ULTRA-LITE

®

: Use on 12-48VDC only. Average load current approximately 1A@12 vdc.

FIRE-FLASH: Use on 12-24VDC only. Average load current approximately 1.5A@12 vdc.

Red wire is Positive
Black wire is Negative

Use the fuse loop included for protection. Locate as close to the battery as possible. Failure to use
fuse loop voids warranty. To install fuse loop, cut loop in two and remove one-half inch insulation
from each end. Connect one end to Positive, the other end to the red lead of the strobe light.
Connect black lead to vehicle ground.