Installation – Dynojet 250: Safety Switch User Manual

Page 3

Advertising
background image

Installation

1) Remove the cover on the wire junction box.
2) Loosen the set screws that hold the jumper wire, and

then remove the jumper wire.

3) Feed the yellow and black wires that are attached to the

safety switch through the grommet hole on the right rear
side of the dyno.

4) Feed the yellow and black wires through side of the wire

junction box.

5) The wires from the switch are to be installed across where

the jumper lead was removed. Wire so the yellow from
the switch lines up with the yellow lead on the bottom of
the terminal strip. Wire the black lead from the switch so
that it lines up the black wire on the bottom of the terminal
strip.

6) The safety switch needs to be mounted at the entry of the

dyno cell. The switch is “open” when the plunger is out,
and “closed” when the plunger is depressed. Mount the
switch on the dyno cell door / access gate so that the
switch is closed when the door is closed. When the door
is opened, the switch will “open” and the the dynamometer
will stop running.

black lead

yellow lead

remove