A P P E N D I X A
Installation

A-2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

INSTALLATION

This section describes the procedures to remove the standard air brake system, install
the proportional air brake system, and wire the Breakout board.

R

EMOVING

THE

S

TANDARD

A

IR

B

RAKE

S

YSTEM

1

Turn off the power on the DynoWare EX+ hardware.

2

Shut off and release the air pressure to the air pressure regulator.

3

Remove the two black wires from the wiring block labeled BRAKE on the
Breakout board.

4

Remove the yellow and black wires from the wiring block labeled PRESS on the
Breakout board.

5

Disconnect the 3/8-inch air hose from the fitting on the air brake control switch.
The air brake control switch is located on top of the right side air canister.
Note: Leave the air hose with the dyno as it will be used later.

6

Unscrew and remove the air brake control switch.

Figure A-2: Remove the Standard Air Brake

brake

press

air hose

air brake

control switch