Dynojet Air Pump III Troubleshooting Guide User Manual

Air pump iii troubleshooting guide, Warnings filter assembly

Advertising
background image

For assistance, call Dynojet Technical Support at 1-800-992-3525, visit www.dynojet.com, or write to Dynojet at 2191 Mendenhall Drive, North Las Vegas, NV 89031.

P/N 98199105 • Version 3

© Copyright 2001-2003 Dynojet Research, Inc. All Rights Reserved. 07/2003SD

Warnings

Filter Assembly

The sensor and the copper sample tube are hot. Before touching
the sensor or the sample tube, make sure it has cooled.

Keep the air pump assembly upright. Tipping the pump assembly
may result in damage to the sensor.

The Air Pump Assembly has a one year warranty.

Remember to empty the exhaust collection bottles regularly.

Leaks in the system will result in erroneous readings. Verify there

are no cracks or holes in the hoses and filter bowl. Verify the sensor is seated
properly in the sensor block.

To ensure accurate readings, pump head maintenance should be

performed every six months, or sooner, depending on usage.
Refer to the Air Fuel Ratio Module Installation and User Guide for pump
maintenance instructions.

Do not allow the filter bowl to fill with water during operation.

Refer to the Air Fuel Ratio Module Installation and User Guide for filter
bowl information.

Before assembling the filter, lubricate the threads on the filter stem
and filter bowl using the grease provided with the replacement

filters or a similar grease. Do not use silicone. The filter stem may break
if not lubricated.

Running the pump with the filter clogged, hose kinked, or filter
removed will damage the pump and void the warranty.

Warm up the vehicle before placing the copper sample tube in the
exhaust to avoid drawing excess water through the pump assembly.

Before turning the pump on, verify there is no water in the filter
bowl. Always empty the bowl before turning the pump on.

Always allow the air pump to run after the dyno runs are complete

to clear all water from the filter bowl and allow the air pump to cool.

AIR PUMP III TROUBLESHOOTING GUIDE

T

T

T

Refer to the Air Fuel Ratio Module Installation and User Guide for

instructions on cleaning and replacing the filter.

If cleaning the filter does not result in free air flow, replace the filter. Be sure

to check for other restrictions in the system.

Refer to the back of this card for the filter assembly and other common

replacement parts.

A clogged filter may cause erroneous readings or slow response. Clean
the filter daily or more often depending on usage.

Refer to the Air Fuel Ratio Module Installation and User Guide for

proper operating and maintenance procedures. Failure to follow proper

procedures may result in inaccurate data or damage to the equipment.

This manual can be found on your WinPEP CD or at

www.dynojet.com/manuals.shtml.

sensor

exhaust

collection bottles

filter assembly

copper

sample tube

power
switch

Advertising