The cooling system also features a high temperature thermal safety system,
which will activate a circuit if the operating temperature goes above 200
degrees F. This circuit will automatically turn off the output of the system in
the event of overheating. It will automatically reset itself as soon as the unit
cools down to a safe operating temperature.

NOTE: the D.I. will continue to operate normally even when the amplifier is
in thermal safety mode. Only the stage sound will be lost.

IMPORTANT NOTE: Excessive heat is a Very Bad Thing and can
result in severe damage to your amplifier. DO NOT bypass or
disconnect any part of your thermal safety system. Doing so will
immediately void your warranty!


Combination Power Cord Jack and Fuse Holder
– The removable power
cord is attached here. To access the fuse holder, pull the holder out of the top
of the power receptacle. Your unit was shipped with a spare fuse inserted in
the fuse carrier. USE ONLY THE SAME SIZE AND TYPE FOR
REPLACMENT. Using a fuse with a different rating than specified is a
VERY BAD THING and can cause damage to your amplifier.
All
models come with a holder marked (FUSE) or (115/230) and are factory
configured for 100/120/ 230/240 only and must be adapted by a service tech
for any voltage change.

Fuse Requirements:

USA @ 120 Volts /60 HZ – 4 Amps, 5 x 20 mm GMC/T/slow blow
Europe @ 240 Volts/50 Hz – 2 Amps, 5 x 20 mm GMC/T/slow blow
Japan @ 100 Volts/60 Hz – 5 Amps, 5 x 20 mm GMC/T/slow blow

IMPORTANT NOTE: Always use slow blow or time delay type fuses.
Do not use fast blow fuses.

To convert your amplifier from US to European fusing, remove the Fuse
Holder and insert a 3 Amp slow blow fuse. Flip the fuse holder over and
reinsert.