This switch turns off your internal and external speakers for quiet
practicing with the headphones.

BACK PANEL FEATURES

AC POWER INLET/ FUSE

This is where you plug in your AC line cord. This is also where the fuse
is located. The fuse for US operation is a 2 amp. 5x20 MM slow-blow
type fuse. In Europe, use a 1 amp @ 240v slow-blow fuse and the
appropriate AC connector for your country. Make certain that your unit is
set for the correct voltage for your country.
Replace your fuse only with the same size and type.

The unit is set at the factory to operate at the correct voltage for your
country. It can easily be changed from the original factory setting to
operate at 100/115/220/230-240VAC. You can change from 230v to
115v by turning over the fuse holder and doubling the size fuse for the
115v operation. Setting the unit for 220VAC and 100VAC operations
require that a jumper be moved in the power supply PC board inside the
unit. Please refer this to a qualified service technician only.

There is

serious risk of damage to the unit and potential injury to yourself if
this is done incorrectly.

INTERNAL THERMAL PROTECTION SYSTEM

Your unit is fully protected by an automatic thermal safety system that
meets the UL-813, CSA, and CE standards for safety. If your unit is
played too hard and too long and it accumulates too much heat load, or
if an amplifier malfunction occurs, the thermal safety system may
engage.

If this happens, your unit may temporarily go into the thermal standby
mode. This is a normal operation of the safety system. In the standby
mode, the unit will remain operating and all the pilot lights will stay on,
but the audio output to the speaker will be shut down until the unit
reaches a safe operating temperature. The D.I. will continue to operate

Advertising