GENERAL SPECIFICATIONS

Size

3.5” x 19” x 14.5”

Weight

32 Lbs.

EIA rack

2 Space w/ min. clearance

Power Output

@ 8_: 2 x 300 Watts RMS; @ 4_: 2 x 600 Watts RMS;
@ 2_: 2 x 750 Watts RMS (Both channels driven)

Bridge Mode

@ 8_: 1200 Watts RMS; @ 4_: 1550 Watts RMS

Headroom

+3dB min.

Damping Factor

better than 100 from 20Hz to 1Khz

Freq. Response

10Hz to 20KHz +/- 2dB

Distortion THD

< .1 %

Power Requirements – The WT-1550 needs a separate properly grounded
20 Amp circuit @ 120 Volts for correct operation and best sound quality.
FOR YOUR SAFETY DO NOT REMOVE OR MODIFY THE
GROUND ON YOUR POWER CABLE.

Fuse Requirements:

USA @ 120 Volts /60 HZ - 12 Amps, 5 x 20 mm GMC/T/slow blow
Europe @ 240 Volts/50 Hz - 6 Amps, 5 x 20 mm GMC/T/slow blow
Japan @ 100 Volts/60 Hz - 14 Amps, 5 x 20 mm GMC/T/slow blow

Operation and Power Requirements – For best electrical operation and
sound quality this unit should have a properly grounded, dedicated 20
Amp circuit for itself.

FRONT PANEL FEATURES

The WT-1550 has several unique features. Each channel is equipped with a
Volume, Bass and Treble controls, and an output limit level indicator.

Volume Control – This control sets the level of signal going to the amplifier
output stage. The further the control is turned to the right, the less signal is
required to drive the amplifier to full output.