STEP #6 INSTALL FRAME COMPONENTS

A. Snap-in PVC pocket fillers into the perimeter framing members.

B. Plug the ends of the exterior portion of the vertical mullions with backer rod. Recess

the backer rod at least 1/4” from each end and apply a generous amount of sealant to
cover the ends of the mullions. Tool the sealant flush with the end of the mullion.

BACKER ROD

PERIMETER PVC

POCKET FILLER

PERIMETER PVC

POCKET FILLER

JAMB

INTERMEDIATE VERTICAL

HEAD

VERTICAL FILLER

Section II: Frame Unit Assembly & Frame Sealing