Dc voltage table – transistors and diodes – Elecraft KX1 Manual User Manual

Page 93

Advertising
background image

E-6

DC Voltage Table – Transistors and Diodes

NOTES: Measurements were made with a 50-ohm dummy load connected and a supply voltage of 13 V. The 30- meter option
was installed (KXB30) and the ATU was removed (KXAT1). In general, your measurements should be within 10% of the values
shown. Pins NOT listed in the table should indicate 0.0 volts DC. Pins marked with (*) are hard to measure due to noise
pickup. Shaded areas show transmit-mode measurements (using TUNE).

Ref. Pin VDC Ref. Pin VDC Ref. Pin VDC Ref. Pin VDC Ref. Pin VDC

D1 A 13.33

Q1 D 13.5 Q7 B 0.7

(on)

K

10.4

G

0.34

C

*

D2

A

13.8

S

1.77

Q8

B

4.39

K

13.5

Q2

D

4.44

C

5.61

D3

A

9.0

G

3.44

E

3.74

K

13.5

S

4.44

Q9

B

0.3*

D4

K

0.3*

Q3

D

4.45

C

1.39

D5

K

5.8

G

3.44

E

0*

D6

K

5.8

S

4.45

D7 K 13.5 Q4 E 0.23

B

0.94

C

2.14

Q5

E

2.24

B

2.14

C

13.5

Q6

C

13.5