Step 1

This system may have come with sample plugs. If so, please remove correctly by following instructions below before installation.

WARNING:

NEVER ATTEMPT TO REMOVE TUBING OR SAMPLE PLUGS BY JUST PULLING. Follow simple instructions

illustrated below to remove properly.

INSPECT:

Inspect the fitting for any damage from shipping, handling and/or delivery. STOP, if collet is damaged in any way;

call, fax or e-mail customer service for a replacement fitting.

Step 2 Making the Connections from Inlet/Supply Connection to Unit and from Unit to the dispenser or other device being supplied.

Firmly insert the tubing completely into the fitting. You may feel a resistance at the o-rings when you insert the tubing.

Step 2a Connect the orange/red tubing from the installed Inlet/Supply Connection into the left side of the unit. This is the raw supply

water into the unit. Insert and press the tubing firmly and completely into the fitting.

Step 2b Connect the blue tubing from the right of the unit. This is the filtered water line. Insert and press the tubing firmly and com-

pletely into the fitting.Now connect that blue tubing to the dispenser or other device(s) chosen to get filtered water.

NOTE:

EWS does not provide a dispenser with the Model No. SS Single-Stage unit. Can be purchased separately.

WARNING:

Water flow is one direction. Make sure never to reverse directions.

Never Pull Tube Out To

Remove

Push Collet In To Release

To Insert, Press Tubing In

Firmly and Completely

Make sure tubing end is

straight and not flattened

Connection of Tubing from Supply and to a Dispenser or Other Device(s)

CAUTION:

Always leave the tubing provided to allow lifting the unit for filter replacement and maintenance.Make sure tub

ing has gentle curves. Roll and secure as needed. Do not bend or kink tubing. We do not recommend shorten-

ing the tubing, however, If needed, at end, cut tube straight and do not flatten. Avoid any tubing contact to hot water

line.
WARNING: NEVER ATTEMPT TO REMOVE TUBING BY JUST PULLING. Follow simple instructions illustrated above to remove properly.
INSPECT: Upon installation, inspect the connection and give the tubing a gentle “tug” to insure proper connection and integrity of the

fitting.

Inspect the fitting for any damage from shipping, handling, delivery, and/or installation.

STOP, if collet is damaged in any way; call, fax or e-mail customer service for a replacement fitting.

Test Integrity of Fitting:

Give a Gentle “Tug”

To Insure

Proper Connection

See All Cautions,

Warnings and

Inspections

Placement or Locating the Filtration Unit

Always assume for enough space and tubing to remove, move and/or adjust

for filter replacement and maintenance.

Mounting the unit to a wall, cabinet side or other vertical surface, a minimum clearance of 4” will be required to allow for filter replace-

ment. Please see the following procedures:
Step 1 The filter cartridge for the unit is included. Locate the filter cartridge.
Inserting the filter cartridge: At the blue top of filter cartridge find the side with two (2) notches. Line the notches up and insert filter

cartridge into the filter head assembly. Once cartridge is fully inserted into the head turn clockwise and completely lock into position.
Step 2 Once filter system has been fully assembled, mark pilot holes using the bracket as a template.

Step 3 Using a drill bit or punch, drill a hole or punch as a starter hole to catch the mounting screws.
WARNING: ALTERNATIVE FASTENING METHOD MAY BE REQUIRED FOR PLASTER BOARD, PARTICLE BOARD OR SIMILAR

MATERIAL INSTALLATION. USE SAFETY GLASSES OR OTHER EYE PROTECTION TO PREVENT POSSIBLE EYE INJURY DUE

TO FLYING PARTICLES.
Step 4 Set mounting screws (provided) with screw driver. Leave a 1/4” gap between the screw head and mounting surface to allow

the bracket to slide on easily.

Step 5 Slide the bracket over screws and hang the unit. Make sure unit is level. Now make the connections of tubing to/from the