Chief Manufacturing Structural Ceiling Plate with Flex Joint CMA-345 User Manual

Structural ceiling plate with flex joints, Cma-345, Figure 1. cma-345 dimensions

Advertising
background image

CHIEF MANUFACTURING INC. 8803-000019
1-800-582-6480
952-894-6280 FAX 952-894-6918

2003 Chief Manufacturing

12800 HIGHWAY 13 SOUTH, SUITE 500

www.chiefmfg.com

SAVAGE, MINNESOTA 55378 USA

01/03

I N S T A L L A T I O N I N S T R U C T I O N S

STRUCTURAL CEILING PLATE WITH FLEX JOINTS

CMA-345

The CMA-345, Structural Ceiling Plate with Flex Joint minimizes the transfer of shock and extreme
vibration from the plate to the equipment. By using any length of standard 1 1/2” NPT pipe threaded on both
ends, or extension column, you can extend the height capabilities to meet your needs.

WARNING: IMPROPER INSTALLATION MAY RESULT IN SERIOUS PERSONAL INJURY!

When mounting Chief Manufacturing accessories, the structural system and mounting method
MUST be capable of supporting 5 times the combined weight of the total installation.
The maximum weight to be installed on the ceiling plate is 500 pounds (226.8 Kg).

Unpack and check contents:
(1) Structural Ceiling Plate CMA-345

(1) 5/16-18 Allen Set Screw

(1) 5/32” Allen Wrench

INSTALLATION INSTRUCTIONS

1. Secure ceiling plate to structural member. (SEE WARNING ABOVE) Bolt hole spacing is shown on

Figure 1.

2. Thread your standard NPT 1 1/2” pipe or extension column into ceiling plate, tighten securely.
3. . Install and securely tighten the 5/16 – 18 socket set screw.

3.13

6.25

3.25

6.50

6X %%c.38

3.36

7.25

7.25

1 1/2" NPT

Figure 1. CMA-345 Dimensions

Advertising