Capillary tube length conversion chart, Example – Just Better Copper Capillary Tubing User Manual

Page 2

Advertising
background image

This conversion chart enables the user to translate

the recommended length of tube diameter into sizes

stocked by J/B. In using the chart it is recommended

that conversions be made using factors within the

unshaded area.

TO USE CHART

(1) Locate recommended cap tube I.D. in left hand

column.

(2) Read across and find conversion factor under

copper cap tube size.

(3) Multiply the given length of the recommended cap

tube by the conversion factor.

Part No.

TC-26

TC-31

TC-36

TC-42

TC-44

TC-49

TC-50

TC-54

TC-55

TC-59

TC-64

TC-70

TC-75

TC-80

TC-85

TC-90

TC-100

Tube I.D.

.026

.031

.036

.042

.044

.049

.050

.054

.055

.059

.064

.070

.075

.080

.085

.090

.100

.024

1.44

.025

1.20

.026

1.00

2.24

.028

.72

1.59

.030

.52

1.16

.031

.45

1.00

2.00

.032

.86

1.75

.033

.75

1.54

.034

.65

1.35

.035

.58

1.16

2.31

.360

.50

1.00

2.10

.037

.45

.90

1.79

2.22

.038

.39

.80

1.59

1.92

.039

.35

.71

1.41

1.75

.040

.31

.62

1.25

1.55

2.51

.041

.28

.56

1.12

1.38

2.26

2.50

.042

.25

.50

1.00

1.24

2.03

2.23

.043

.23

.45

.87

1.11

1.83

1.98

.044

.20

.39

.81

1.00

1.62

1.79

.045

.35

.73

.90

1.47

1.60

2.32

.046

.32

.67

.82

1.34

1.47

2.08

2.27

.047

.59

.74

1.20

1.31

1.89

2.06

.048

.54

.67

1.10

1.20

1.72

1.87

.049

.49

.61

1.00

1.09

1.55

1.69

.050

.45

.56

.91

1.00

1.43

1.56

2.14

.051

.41

.51

.84

.93

1.31

1.44

1.96

.052

.47

.76

.85

1.19

1.32

1.78

.053

.43

.69

.78

1.09

1.20

1.64

.054

.39

.65

.70

1.00

1.09

1.52

2.18

.055

.36

.59

.64

.92

1.00

1.38

2.00

.056

.54

.60

.85

.94

1.27

1.85

.057

.50

.55

.79

.87

1.17

1.72

.058

.46

.51

.73

.80

1.07

1.56

.059

.42

.47

.67

.73

1.00

1.44

2.18

.060

.39

.43

.62

.67

.93

1.33

2.04

.064

.32

.47

.50

.69

1.00

1.50

2.07

.070

.30

.33

.46

.67

1.00

1.37

1.84

.075

.48

.73

1.00

1.37

1.75

.080

.54

.74

1.00

1.32

1.71

.085

.57

.76

1.00

1.29

.090

.43

.62

.76

1.00

1.62

.095

.46

.60

.79

1.27

.100

.48

.62

1.00

.105

.49

.80

.110

.65

.115

.53

.120

.43

CAPILLARY TUBE LENGTH CONVERSION CHART

(4) The resultant length (Min. 5 feet/Max.16 feet) of

copper cap tube will give the same flow charac-

teristics as the original recommended cap tube.

EXAMPLE

Recommended cap tube: 9'–.040 I.D.
Locate .040 in left hand column and reading across

gives the following conversion factor: No. TC-36

(.62) and TC-42 (1.25).
Multiply the recommended cap tube length of 9'

by the conversion factor gives the following results:

5-1/2"-TC-36 and 11-1/4'–TC-42. Either of these

two cap tubes will give the same results as the

original cap tube of 9'–.040 I.D.

Advertising