Mains electricity connection, Electrical information, Troubleshooting – CDA EXTRACTORS CIGE9 User Manual

Page 6

Advertising
background image

DOUBLE POLE SWITCHED

FUSED SPUR OUTLET

USE A 3 AMP FUSE

Mains Electricity Connection

THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY BY A COMPETENT PERSON, USING FIXED
WIRING VIA A DOUBLE POLE SWITCHED FUSED SPUR OUTLET AND PROTECTED BY A 3A FUSE.

We recommend that the appliance is connected by a qualified electrician, who is a member of the N.I.C.E.I.C. and who will
comply with the I.E.E. and local regulations.

The wires in the mains lead of this appliance are coloured in accordance with the
following code:

BLUE = NEUTRAL, BROWN = LIVE.

As the colours of the wires in the mains lead for the appliance may not correspond
with the coloured markings identifying the terminals connecting to the fused spur,
proceed as follows:

The wire which is coloured blue must be connected to the terminal marked N

(Neutral), or coloured black.

The wire which is coloured brown must be connected to the terminal marked

L (Live), or coloured red.

NOTE: USE A 3A FUSE

Assembly and electrical connection should be carried out by competent personnel.

When installing this product we recommend you seek the help of another individual.

IMPORTANT: THIS APPLIANCE IS A CLASS II APPLIANCE (DOUBLE INSULATED) AND IS NOT INTENDED TO
BE EARTHED. DO NOT FIT AN EARTH LEAD TO THIS EXTRACTOR.

Do not mount the isolation switch behind the chimney section. It is a requirement that you must be able to isolate the
extractor from the mains electrical supply after installation.

This appliance is intended to be connected to the mains electrical supply by means of an isolation switch and fused spur
and is intended to be protected by a 3A fuse. The use of a 13A fuse can cause damage to the internal wiring in the event
of a fault, and may also invalidate the warranty.

Electrical Information

Mains electrical voltage: 230 – 240Vac.
Total rated power consumption: 230W.

Troubleshooting

If your extractor is not working:
1. Check that the mains supply has not been switched off.
2. Check that the fuse in the spur has not blown.

Contact CDA Customer Care
A : Customer Care Department, The CDA Group Ltd, Harby Road, Langar, Nottinghamshire, NG13 9HY
T : 01949 862 012 F : 01949 862 003 E : [email protected] W : www.cda.eu

5

Advertising