Introduction cp6002 – Kontron CP6002 User Manual

Page 40

Advertising
background image

Introduction

CP6002

Page 1 - 20

ID 1036-6431, Rev. 3.0

P R E L I M I N A R Y

In addition, the CP6002-R2-MC complies with the following standards as well.

Note ...

Kontron performs comprehensive environmental testing of its products in accor-
dance with applicable standards.

Customers desiring to perform further environmental testing of Kontron prod-
ucts must contact Kontron for assistance prior to performing any such testing.
This is necessary, as it is possible that environmental testing can be destructive
when not performed in accordance with the applicable specifications.

In particular, for example, boards without conformal coating must not be
exposed to a change of temperature exceeding 1K/minute, averaged over a
period of not more than five minutes. Otherwise, condensation may cause irre-
versible damage, especially when the board is powered up again.

Kontron does not accept any responsibility for damage to products resulting
from destructive environmental testing.

Table 1-4:

Additional Standards for the CP6002-R2-MC

TYPE

ASPECT

STANDARD

REMARKS

Environmental

Random Vibra-
tion (Broadband)

ANSI / VITA 47, Class V2

Test parameters:
• 5-100 (Hz) frequency range: +3dB slope
• 100-1000 (Hz) freq. range: 0.04 (g²/Hz)
• 1000-2000 (Hz) freq. range: -6dB slope
• 7.619 g (rms)
• 60 (min) test duration/axis
• 3 axes

Single Shock

ANSI / VITA 47, Class OS1

Test parameters:
• 20 (g) acceleration
• 11 (ms) shock duration half sine
• 3 shocks per direction
• 6 directions
• 5 (s) recovery time

Advertising