6 standards, 6 standards - 12, Introduction am4120 – Kontron AM4120 User Manual

Page 28

Advertising
background image

Introduction

AM4120

Page 1 - 12

ID 1045-6958, Rev. 1.0

1.6

Standards

The AM4120 complies with the requirements of the following standards.
Table 1-3: Standards

COMPLIANCE

TYPE

STANDARD

TEST LEVEL

CE

Emission

EN55022
EN61000-6-3
EN300386

--

Immission

EN55024
EN61000-6-2
EN300386

--

Electrical Safety

EN60950-1

--

Mechanical

Mechanical Dimensions IEEE 1101.10

--

Environmental and
Health Aspects

Vibration
(sinusoidal, operating)

GR-63-CORE
EN300019-2-3
IEC61131-2
IEC60068-2-6

5-150 [Hz] frequency range
1 [g] acceleration
1 [oct/min] sweep rate
10 sweeps/axis

3 directions: x,y,z

Shock (operating)

EN300019-2-3
IEC61131-2
IEC60068-2-27

15 [g] acceleration
11 [ms] pulse duration
3 shocks per direction
5 [s] recovery time
6 directions, ±x, ±y, ±z

Climatic Humidity

IEC60068-2-78

93% RH at 40°C, non-condensing
(see note below)

WEEE

Directive 2002/96/EC

Waste electrical and electronic equipment

RoHS

Directive 2002/95/EC

Restriction of the use of certain
hazardous substances in electrical and
electronic equipment

Note ...

Kontron performs comprehensive environmental testing of its products in accor-
dance with applicable standards.
Customers desiring to perform further environmental testing of Kontron prod-
ucts must contact Kontron for assistance prior to performing any such testing.
This is necessary, as it is possible that environmental testing can be destructive
when not performed in accordance with the applicable specifications.
In particular, for example, boards without conformal coating must not be
exposed to a change of temperature exceeding 1K/minute, averaged over a
period of not more than five minutes. Otherwise, condensation may cause irre-
versible damage, especially when the board is powered up again.
Kontron does not accept any responsibility for damage to products resulting
from destructive environmental testing.