6 electrical specification, 1 supply voltage, 2 power supply rise time – Kontron COMe-bSC2 User Manual

Page 20: 3 supply voltage ripple, 4 power consumption, Electrical specification, Supply voltage, Power supply rise time, Supply voltage ripple, Power consumption

Advertising
background image

COMe-bSC2 / Product Specification

3.6

Electrical Specification

3.6.1

Supply Voltage

Following supply voltage is specified at the COM Express® connector:

VCC:

8.5V - 18V (20V@nonECC)

Standby:

5V DC +/- 5%

RTC:

2.5V - 3.47V

- 5V Standby voltage is not mandatory for operation.
- Extended Temperature (E1) variants are validated for 12V supply only

3.6.2

Power Supply Rise Time

» The input voltages shall rise from ≤10% of nominal to within the regulation ranges within 0.1ms to 20ms.

» There must be a smooth and continuous ramp of each DC input voltage from 10% to 90% of its final set-point

following the ATX specification

3.6.3

Supply Voltage Ripple

» Maximum 100 mV peak to peak 0 – 20 MHz

3.6.4

Power Consumption

The maximum Power Consumption of the different COMe-bSC2 variants is 10 - 73W (100% CPU load on all cores; 90°C CPU
temperature). Further information with detailed measurements are available in Application Note KEMAP054 available on

EMD Customer Section

. Information there is available after registration.

20

Advertising