COM Express® Eval Carrier Type 6

10

3.5

Environmental Specification

Ambient temperature

»

Operating: 0 to +60 °C

»

Non-operating: -30 to +85 °C

Humidity

»

Operating: 10% to 90% (non condensing)

»

Non operating: 5% to 95% (non condensing)

3.6

MTBF

The following MTBF (Mean Time Between Failures) values were calculated using

a combination of manufacturer’s test data, if the data was available, and a

Bellcore calculation for the remaining parts. The Bellcore calculation used

is “Method 1 Case 1”. In that particular method the components are assumed to

be operating at a 50 % stress level in a 40° C ambient environment and the

system is assumed to have not been burned in. Manufacturer’s data has been

used wherever possible. The manufacturer’s data, when used, is specified at

50° C, so in that sense the following results are slightly conservative. The

MTBF values shown below are for a 40° C in an office or telecommunications

environment. Higher temperatures and other environmental stresses (extreme

altitude, vibration, salt water exposure, etc.) lower MTBF values.

»

System MTBF: 227731 hours @ 40°C