Environmental specification, Mtbf, 5 environmental specification – Kontron COMe Ref. Carrier T2 User Manual

Page 16: 6 mtbf

Advertising
background image

COM Express™ miniBaseboard Type 2

/ Specification



11

3.5 Environmental Specification

Ambient temperature

»

Operating: 0 to +60 °C

»

Non-operating: -30 to +85 °C

Humidity

»

Operating: 10% to 90% (non condensing)

»

Non operating: 5% to 95% (non condensing)

3.6 MTBF

The following MTBF (Mean Time Between Failures) values were calculated using a combination of manufacturer‟s test
data, if the data was available, and a Bellcore calculation for the remaining parts. The Bellcore calculation used is
“Method 1 Case 1”. In that particular method the components are assumed to be operating at a 50 % stress level in a
40° C ambient environment and the system is assumed to have not been burned in. Manufacturer‟s data has been
used wherever possible. The manufacturer‟s data, when used, is specified at 50° C, so in that sense the following
results are slightly conservative. The MTBF values shown below are for a 40° C in an office or telecommunications
environment. Higher temperatures and other environmental stresses (extreme altitude, vibration, salt water
exposure, etc.) lower MTBF values.

»

System MTBF ETXexpress® miniBaseboard:

192796 hours

»

System MTBF COM Express™ miniBaseboard Type 2:

144767 hours