COMe-cPC2 / Product Specification

2.6

Environmental Specification

2.6.1

Temperature Specification

General Specification

Operating

Non-operating

Commercial grade

0°C to +60°C

-30°C to +85°C

Extended (E1)

-25°C to +75°C

-30°C to +85°C

Industrial grade (E2)

-40°C to +85°C

-40°C to +85°C

Standard modules are available for commercial grade temperature range. Please see
chapter Product Specification for available variants for extended or industrial temperate
grade

With Kontron heatspreader plate assembly

The operating temperature defines two requirements:

» the maximum ambient temperature with ambient being the air surrounding the module.

» the maximum measurable temperature on any spot on the heatspreader's surface

Without Kontron heatspreader plate assembly

The operating temperature is the maximum measurable temperature on any spot on the module's surface.

2.6.2

Humidity

» Operating: 10% to 90% (non condensing)

» Non operating: 5% to 95% (non condensing)