Operation – Chicago Electric Model 55250 User Manual

Page 7

Advertising
background image

Page 7

SKU 55250

For technical questions, please call 1-800-444-3353.

Operation

Controls and Indicators

Welding

Caution: Before arc welding, read and understand all safety precautions and warnings
listed on pages 2 through 5.

1.

If using non-flux core wire, connect and secure the Argon/CO

2

gas hose to the rear of the MIG Welder. (If using flux core wire,
protective gas is not required.)

2.

Attach the Ground Cable with Clamp (15) as close as possible

to the metal object to be welded, or to the metal work bench
where the object is mounted and electrically connected.

3.

Set the desired welding current (30~120 amps) for the type of metal being welded

using the Min/Max Switch and 1/2 Power Level Switch.

Refer to the power setting table on the next page. Thinner metals use lower current.

Heavier metals use higher current.

4.

Verify that the On/Off Switch is in the OFF position, then plug the MIG Welder Line

Cord into a dedicated, 220 VAC, 20 amp line with delayed action type circuit breaker

11.

A licensed electrician must connect a 220 V~ plug (not supplied) to the line cord.

Green wire = ground; Black wire = hot (110 V~, Leg 1); White wire = hot (110 V~, Leg 2)

Handheld Shaded Face Shield

Assemble the Handheld Shaded Face Shield as illustrated in its Assembly Drawing at the
end of this manual.

On / Off Switch

Min / Max Switch

1 / 2 Power Level Switch

Overload-shutdown
Indicator Lamp

Wire Feed Speed Control

Line Cord

Ground Cable with Clamp (15)

Welding Torch Cable (16)

Advertising