3.10 Thermal Management, Heatspreader and Cooling Solutions

A heatspreader plate assembly is available from Kontron Europe GmbH for the ETX®-OH. The heatspreader plate on top of
this assembly is NOT a heat sink. It works as a ETX® 3.0-standard thermal interface to use with a heat sink or external
cooling devices.

External cooling must be provided to maintain the heatspreader plate at proper operating temperatures. Under worst-
case conditions, the cooling mechanism must maintain an ambient air and heatspreader plate temperature on any spot of
the heatspreader's surface according the module specifications:

» 60°C for commercial grade modules

» 75°C for extended temperature grade modules (E1)

» 85°C for industrial temperature grade modules (E2/XT)

The aluminum slugs and thermal pads or the heat-pipe on the underside of the heatspreader assembly implement thermal
interfaces between the heatspreader plate and the major heat-generating components on the ETX®-OH. About 80 percent
of the power dissipated within the module is conducted to the heatspreader plate and can be removed by the cooling
solution.

You can use many thermal-management solutions with the heatspreader plates, including active and passive approaches.
The optimum cooling solution varies, depending on the ETX® 3.0 application and environmental conditions. Active or
passive cooling solutions provided from Kontron Europe GmbH for the ETX®-OH are usually designed to cover the power
and thermal dissipation for a commercial grade temperature range used in a housing with proper air flow.

Documentation and CAD drawings of ETX®-OH heatspreader and cooling solutions are provided at

http://emdcustomersection.kontron.com

.