2.4

Electrical Specifications

INPUT

OUTPUT

REGULATION

PARAMETER

CONDITIONS / DESCRIPTION

MIN

NOM

MAX

UNITS

Input Voltage - AC

Continuous input range.

85

264

VAC

Input Frequency

47

63

Hz

Hold-up Time

20

ms

Input Protection

Non-user serviceable, internally-located input line fuse.

Inrush Surge Current

Internally limited by thermistor and electronic switch.

30

A

Operating Frequency

Switching frequency of main output transformer.

125

145

kHz

PARAMETER

CONDITIONS/DESCRIPTION

MIN

NOM

MAX

UNITS

Efficiency

Full rated load, 115 VAC.

80

%

Minimum Load; V1,
V2, V3

Minimum load required to maintain regulation with no
load on V4.

None

A

Minimum Load, V3

Minimum load on V3 required to maintain regulation on V4.

50% of V4 Load

A

Ripple and Noise

Full load, 20 MHz bandwidth.

See Regulation table

Output Power

250 LFM forced-air cooling.

200

W

Overshoot /
Undershoot

Output voltage overshoot / undershoot at turn-on.

0

%

Regulation

Varies by output. Total regulation includes: line changes
over the specified input range, changes in load starting at
50% load and changing to 100% load.

See Regulation table

Turn-on Delay

Time required for initial output voltage stabilization.

150

ms

Initial Setting Accuracy

±1

%

OUTPUT

VOLTAGE

ADJUSTMENT

RANGE

OUTPUT

CURRENT

LINE

REGULATION

LOAD

REGULATION

RIPPLE & NOISE

%pk-pk (NOTE 1)

V1

+5V

N/A

40A

0.5%

1%

2%

V2

+3.3V

N/A

40A

0.5%

1%

2%

V3

+12V

N/A

5.5A

0.5%

1%

1.3%

V4

-12V

N/A

1.5A

0.5%

1%

1.3%