3 installation, 4 electrical specifications – Kontron CP3-SVE-M180AC User Manual

Page 6

Advertising
background image

PD04: CP3-SVE-M180AC

CPCI Power Supply

Page 6

© 2002 PEP Modular Computers GmbH

RID 24139 PD04, Rev. 01

2.3

Installation

Thanks to its plug-in compatibility this DIN M-type power supply unit allows for an easy instal-
lation, by which the power supply unit’s male DIN M24/8 power connector is inserted into the
backplane’s mating female connector without the need of any intermediate adaptation.

2.4

Electrical Specifications

Input

Output

Warning!
To ensure a safe 5V operation of your equipment it is necessary that
on the backplane 5VL is connected to 5VF and 0VL to 0VF. PEP sys-
tems provide this configuration by default.

The maximum voltage compensation is 0.25V per line.

Input voltage ranges

V

EU

= 187V..264V AC

V

US

= 99V..138V AC

Frequency: 50Hz..60Hz

Voltage switching

Autoranging

Efficiency

Typ. 82%

Input current limitation

Typ.

15A

peak

(cold state)

Typ.

20A

peak

(hot state)

Fuse

6.3 AT

Adjustment range V

o1

, V

o2

± 5%

Status indication

Green LED’s for V

o1

, V

o2

, V

o3

, V

o4

Ripple

V

o1

, V

o2

< 50mV

pp

,

V

o3

, V

o4

< 30mV

pp

Noise voltage

Typ. 50mV

pp

(band width 20MHz)

Temperature coefficient

0.025% / K

Switch on / switch off performance

No overshooting of V

o

(soft-start)

Rise-delay time

< 0.5s

Run-up time

50ms