5 auxiliary signal connectors, Cpci backplane pd05: cp3-bp8-m-rio – Kontron CP3-BP8-M-RIO User Manual

Page 9

Advertising
background image

CPCI Backplane

PD05: CP3-BP8-M-RIO

RID 24229 PD05, Rev. 01

© 2002 PEP Modular Computers GmbH

Page 9

5.5

Auxiliary Signal Connectors

The connection of the auxiliary signals is accomplished by means of the two 5-pole Molex
male connectors JP1 and JP2 as well as the 10-pole LPV male connector JP3. The LPV con-
nector JP3 provides the same signals as JP1 and JP2 taken together.

Figure 7: Orientation and Pinouts of CP3-BP8-M-RIO Connectors JP1 and JP2

Figure 8: Orientation and Pinouts of CP3-BP8-M-RIO Connector JP3

5 4 3 2 1

5 4 3 2 1

JP1

JP2

View from reverse side

Table 6: Pinouts of CP3-BP8-M-RIO
Connectors JP1 and JP2

Pin

Function

JP1

1

EN#

2

GND

3

INH#

4

GND

5

N/C

JP2

1

GND

2

+5V

3

FAL#

4

DEG#

5

PRST#

9

1

3

5

7

10

2

4

6

8

Table 7:

Pinouts of CP3-BP8-M-RIO

Connector JP3

Pin

Function

1

GND

2

EN#

3

GND

4

INH#

5

DEG#

6

FAL#

7

GND

8

PRST#

9

GND

10

+5V

Advertising