5 auxiliary signal connectors, Cpci backplane pd05: cp3-bp8-m-rio – Kontron CP3-BP8-M-RIO User Manual
Page 9
CPCI Backplane
PD05: CP3-BP8-M-RIO
RID 24229 PD05, Rev. 01
© 2002 PEP Modular Computers GmbH
Page 9
5.5
Auxiliary Signal Connectors
The connection of the auxiliary signals is accomplished by means of the two 5-pole Molex
male connectors JP1 and JP2 as well as the 10-pole LPV male connector JP3. The LPV con-
nector JP3 provides the same signals as JP1 and JP2 taken together.
Figure 7: Orientation and Pinouts of CP3-BP8-M-RIO Connectors JP1 and JP2
Figure 8: Orientation and Pinouts of CP3-BP8-M-RIO Connector JP3
5 4 3 2 1
5 4 3 2 1
JP1
JP2
View from reverse side
Table 6: Pinouts of CP3-BP8-M-RIO
Connectors JP1 and JP2
Pin
Function
JP1
1
EN#
2
GND
3
INH#
4
GND
5
N/C
JP2
1
GND
2
+5V
3
FAL#
4
DEG#
5
PRST#
9
1
3
5
7
10
2
4
6
8
Table 7:
Pinouts of CP3-BP8-M-RIO
Connector JP3
Pin
Function
1
GND
2
EN#
3
GND
4
INH#
5
DEG#
6
FAL#
7
GND
8
PRST#
9
GND
10
+5V