Interfaces, 1 power supply input, Jp12 – Kontron CP3-BP2-PB-RIO User Manual

Page 6: Jp11, Pd15: cp3-bp2-pb-rio cpci backplane

Advertising
background image

PD15: CP3-BP2-PB-RIO

CPCI Backplane

Page 6

© 2003 PEP Modular Computers GmbH

RID 24229 PD15, Rev. 01

5.

Interfaces

5.1

Power Supply Input

The V1 ... V4 output voltages from the power supply unit to the backplane are connected via
power bar elements to the respective supply terminals of the power distribution backplane and
the CP3-BP2-PB-RIO backplane. The power bars themselves are specifically designed to fit
the backplane raster and allow additional backplanes to be integrated into a customized
designed system to satisfy almost any application requirements.

5.2

System Monitor and Control Connectors JP11 and JP12

This backplane is provided with two connectors for system monitor and control signal interfac-
ing to external devices. Both are 26-contact, male, double pin-row connectors, and have the
same signal pinout configuration. The system management bus (IPMB0), the power supply
monitor and control signals, and push button reset (PRST#) signal are all implemented on
these connectors.

Figure 4: Orientation and Pinout of the CP3-BP2-PB-RIO SMC Connectors JP11 and JP12

1

13

b
a

JP12

1

13

b
a

JP11

Table 2: Pinout of CP3-BP8-P47-RIO
SMC Connectors JP11 and JP12

Pin

Function

Pin Row A

Pin Row B

1

IMPB0_SCL

GND

2

IMPB0_SDA

IMPB0_PWR

3

N/C

GND

4

N/C

GND

5

N/C

GND

6

INH#

GND

7

FAL#

DEG#

8

PRST#

GND

9

GND

V1 SENSE (+5V)

10

V2 SENSE (+3.3V)

SENSE RTN

11

V3 SENSE (+12V)

GND

12

V1 SHARE (+5V)

V2 SHARE (+3.3V)

13

V3 SHARE (+12V)

GND

Advertising