The mount clamps with screws (supplied), allow the easy and fast mounting of the OmniClient-
156/185/215. Refer to the appropriate unit outline and mounting drawing for the correct
dimensions of cut-outs and air gap clearances required for mounting the unit into a wall or panel.
The OmniClient outline and mounting drawing can be found on our web site

www.kontron.com

Dimension for: OmniClient

156

185

215

Cut-Out for Mounting into a Panel
[mm] (W x H)

394 x 245

462 x 283

527 x 325

Requirements for Mounting
Metal mounting panel thickness
for proper mounting

1.5 – 6

1.5 – 6

1.5 – 9

Used clamps with screws for
mounting the OmniClient to
a panel

6x

8x

Required Tool

#2 Phillips Screw Driver

Proper Torque

Tighten the screws with a torque of 0.5 Nm

Mounting Position

Ensure the vertical and horizontal alignment of the

system/display box.

Table 2: Requirements for OmniClient mounting into a subframe/panel

In order to ensure IP65 front sealing against dust and water, mount the system on a
non-textured surface.
Before you install the OmniClient system into a panel or a
subframe for industrial cabinet, verify the perfect condition of the seal at the rear of
the front plate. The seal has to be in place without surface imperfections/defects
and dirt.