Type a standard & night setback, Laboratory airflow monitors & controls, General description – Plastec Airflow Monitor A User Manual

Page 2: Led & digital

Advertising
background image

General Description

2

Laboratory Airflow Monitors & Controls

TYPE A STANDARD & NIGHT SETBACK

LED & DIGITAL

BENEFITS

• Safety: in accordance with EU laboratory
standard EN 14175
• Ease of installation and maintenance
• Fast and accurate sensor reading
• Attractive design: available in choice of LED or

digital display

RANGE

Versions:

A LED: Monitors airflow, LED lights
A DIGITAL: Monitors airflow, digital read out in

meter per second or feet per minute

FEATURES

• Audio and visual alarm
• 3 Pushbuttons: Fan On/Off, Light On/Off, Mute
• Alarm disabled when fan switch off
• Sash High
• Auxiliary contacts
• A 15 second or 30 second alarm delay

OPTIONS

Surface Box Mounting: Plastic enclosure to

mount the face plate and to avoid profile cutting
the service panel.

Alarm Relay: A remote alarm can be triggered

from a relay on the controller pcb.

Battery Back Up: Red LED alarm is still
functional up to 12 hours when unit loses power.
Custom Resin Stickers: Customizable resin

stickers with logo, address, etc.

COLORS

Plastic fascia is

available in:
- White (Standard)

INTERNATIONAL STANDARDS
COMPLIANCE

In accordance with:
- European laboratory standard EN 14175-2
- Electromagnetic standards EN

61326 : 1997/A1 : 1998/A2 : 2001/A3 : 2003

(Test report RC-05-42060-1) US FCC Part 15

Class B edition 2005 (Test report RC-05-

42060-2-A)
- European RoHS directive governing disposal and

recycling of electronics

- French laboratory standard XPX 15203 of Sept.

1996

- CE

COMPONENTS

• Circuit Board: Panel mounted circuit board to

be installed vertically or horizontally onto fume

cupboard with 2x Ø 2.8 mm / 0.11" screws. IP55

protection ensured by “O” ring seal. Face plate

to be supplied with chemical resistant plastic

sticker (horizontal or vertical) with control/push

buttons on fascia. Surface box mounting optional.

• Numerical and Antistatic Sensor: To be installed

inside fume hood. Sensor measures air speed

variations inside fume hood. Supplied with a

3.5 m (5 m optional) shielded cable with pin

connections onto controller circuit board.

• Power Supply: 115 VAC to 12 VDC power

transformer directly into controller circuit board.

Comes with a wall plug and cord. Adaptor may

be required to fit local power socket.

PACKING

• Supplied in cardboard box which includes con-

troller circuit board, face plate, sensor and power
transformer. Surface box mounting optional.

Advertising