Set options – ProgressiveRC 6 PowerLab User Manual

Page 11

Advertising
background image

Set options

1. Connect PowerLab 6 to a 10–32V DC power supply or Lead Acid battery.
2. Press any button on PowerLab 6’s panel.
3. At

the

Power Source?

screen, use the INC or DEC button to select Battery or DC

Power Supply

(i.e., what is currently powering the PowerLab 6).

4. Press

ENTER

to display the User Preset menu.

5. Press INC+DEC (i.e., press both INC and DEC at the same time) to display the

Options menu (Choose TASK?).

6. Press

INC

or DEC until you see Charger Options, then press ENTER.

7. The

Charger Address?

screen should display PRIMARY CHANNEL (unless you are

running multiple PowerLabs in

Expansion Channel mode

). If it doesn’t, press INC

until you see PRIMARY CHANNEL. Press ENTER.

8. The next screen is the Power Source? Screen. (See

Set Smart Power Management

for instructions on setting the Power Source and Regenerative Discharge options.)

9. Press ENTER until you see the Node Connector? Screen. For more information

about wiring modes, see

FMA Wiring mode vs. XH/EH Wiring mode

.

10. Press ENTER until you see the Decimal Places for Cells? screen. At the Decimal

Places for Cells?

screen, press INC or DEC to select 2 or 3, then press ENTER.

(This controls how many decimal places are displayed in cell voltage data screens.)

11. At the Quiet Charging? screen, press INC or DEC to select Y or N, then press

ENTER

. (Y = no beeps during charging, N = beeps during charging.)

12. At the Speaker Volume? screen, press INC or DEC to set speaker volume, then

press ENTER. (1 = quietest. While setting volume, speaker beeps at volume shown
on screen.)

13. At the Charge Complete Beeps? screen, press INC or DEC to set the number, then

press ENTER. (This controls how many times PowerLab 6 repeats “beep beep beep”
when charging is complete.)

14. At the Preset Changes Always Save? screen, press INC or DEC to select Y or

N

, then press ENTER. (Y = changes made to a User Preset at PowerLab 6 are

always saved to the loaded preset and uploaded to the Charge Control Software.
Setting to N is not recommended, but it provides a way to temporarily override
preset parameters—once you move to another preset, any changes you made
will be lost and the preset will revert to its previous state.) No matter what you
choose for this option, you can always over-ride charge and discharge rate on-
the-fly at the PowerLab 6 after a charge is started by pressing ENTER. This
method never saves the changes to the preset in use.

15. At the Choose TASK? screen:

Press

INC

or DEC to select another setup function.

Press

BACK

to display the User Preset menu.


See also

CCS Options tab

Tip:

A setting is saved as soon as you change it. Also, you don’t have to go

through the entire sequence below—at any time, you can press and hold the
BACK

button to return to the User Preset menu.

11