ProgressiveRC RSP-2000 series User Manual

R s p - 2 0 0 0, 2000w single output power supply, Specification

Advertising
background image

SPECIFICATION

RSP-2000-12

RSP-2000-24

MODEL

DC VOLTAGE

RATED CURRENT

CURRENT RANGE

RATED POWER

OUTPUT

VOLTAGE ADJ. RANGE

LINE REGULATION

LOAD REGULATION

SETUP, RISE TIME

HOLD UP TIME (Typ.)

VOLTAGE RANGE

Note.5

FREQUENCY RANGE

POWER FACTOR (Typ.)

EFFICIENCY (Typ.)

INPUT

INRUSH CURRENT (Typ.)

LEAKAGE CURRENT

AC CURRENT (Typ.)

Note.5

12V

24V

100A

80A

0 ~ 100A

0 ~ 80A

1200W

1920W

150mVp-p

10.5 ~ 14V

200mVp-p

21 ~ 28V

2.0%

1.0%

1.0%

1.0%

1500ms, 60ms/230VAC at full load

16ms/230VAC at 75% load

10ms/230VAC at full load

90 ~ 264VAC

127 ~ 370VDC

47 ~ 63Hz

0.97/230VAC at full load

87%

COLD START 50A

13A/115VAC

7A/230VAC

16A/115VAC

10A/230VAC

16A/115VAC

10A/230VAC

<2mA / 240VAC

RSP-2000-48

48V

42A

0 ~ 42A

2016W

300mVp-p

42 ~ 56V

1.0%

0.5%

0.5%

0.5%

0.5%

Universal AC input / Full range

Built-in 5V/0.3A, 12V/0.8A auxiliary power

Built-in active PFC function, PF>0.97

Protections: Short circuit / Overload / Over voltage / Over temperature

Forced air cooling by built-in DC fan with fan speed control

Output voltage can be trimmed between 40~115% of the rated output voltage

1U low profile 41mm

Active current sharing up to 8000W(3+1)

Built-in remote sense function

DC OK signal, OTP alarm signal

3 years warranty

High Power density 21.4W/inch

Built-in remote ON-OFF control

3

RIPPLE & NOISE (max.)

Note.2

VOLTAGE TOLERANCE

Note.3

90.5%

92%

Protection type : Constant current limiting, unit will shut down o/p voltage after 5 sec. re-power on to recover

OVER TEMPERATURE

OVERLOAD

OVER VOLTAGE

105 ~ 125% rated output power

14.7 ~ 17.5V

Protection type : Shut down o/p voltage, re-power on to recover

80

5

(TSW1) detect on heatsink of power bridge

75

5

(TSW2) detect on heatsink of o/p diode

Protection type : Shut down o/p voltage, recovers automatically after temperature goes down

29.5 ~ 35V

57.6 ~ 67.2V

PROTECTION

2000W Single Output Power Supply

Features :

R S P - 2 0 0 0

s e r i e s

DC OK SIGNAL

REMOTE SENSE

REMOTE ON/OFF CONTROL

AUXILIARY POWER

The isolated TTL signal out, refer to function manual

Compensate voltage drop on the load wiring up to 0.5V, refer to function manual

By electrical signal or dry contact

Power ON:open

Power OFF:short, refer to function manual

5V @ 0.3A, 12V @ 0.8A

FUNCTION

Adjustment of output voltage, possible between 40 ~ 115% of rated output, refer to function manual

WORKING TEMP.

WORKING HUMIDITY
STORAGE TEMP., HUMIDITY

TEMP. COEFFICIENT

VIBRATION

-35 ~ +70

(Refer to "Derating Curve")

20 ~ 90% RH non-condensing

-40 ~ +85

, 10 ~ 95% RH

0.03%/

(0 ~ 50

)

ENVIRONMENT

OUTPUT VOLTAGE TRIM

10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

File Name:RSP-2000-SPEC 2011-12-27

SAFETY STANDARDS

WITHSTAND VOLTAGE

UL60950-1, TUV EN60950-1 approved

I/P-O/P:3KVAC

I/P-FG:1.5KVAC

O/P-FG:0.5KVAC

ISOLATION RESISTANCE

MTBF

DIMENSION

PACKING

OTHERS

46.3Khrs min.

MIL-HDBK-217F (25

)

295*127*41mm (L*W*H)

SAFETY &

EMC

(Note 4)

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25

/ 70% RH

1.95Kg; 6pcs/12.7Kg/1.15CUFT

Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A

Compliance to EN55022 (CISPR22) Conduction Class B, Radiation Class A ; EN61000-3-2,-3

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25

of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets

EMC directives.

5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. Under parallel operation ripple of the output voltage may be higher than the SPEC at light load condition. It will go back to normal ripple level once the

output load is more than 5%.

EMC IMMUNITY

EMC EMISSION

Advertising