Cell voltage monitor celllog 8m, Quick start – ProgressiveRC 8M CellLog User Manual

Page 8

Advertising
background image


-8-

Cell Voltage Monitor CellLog 8M

TYPE

XXXXXXXXXX


Do not support
the logging!

QUICK START


CellLog Power On

(2 ways: one is connecting the battery through the left 9 Pin socket, the other one is through the USB port),
System self-check, and then shows the SN and version number, the display information are as below:

The first line is the current selected Setting Type (See
detail in P10).

Note: CellLog 8M has no Logging function, if it is necessary,
please choose CellLog 8S.


Voltage Monitor

There are 4 interface choices, which can be shifted by <▲> or <▼>buttons.
















As the left pictures: the ‘7‘ in ‖7S‖ means cell counts; ‘6H‘
means the 6

th

cell voltage is the highest; ‘1L‘ means the 1

st

cell voltage is the lowest.
If the monitor voltage trigger alarm, the corresponding
voltage and alarm display (LOW, OVER or DIFF) shows
alternatively.
The cell number and (L, O, D) shows alternatively.

LOW‘ or ‗L‘ means: Low voltage alarm
OVER‘ or ‗O‘ means: Over voltage alarm
DIFF‘ or ‗D‘ means: Voltage difference alarm. They will be

displayed at the same time at the highest and the lowest
cell voltage interface.


Monitor the pack voltage
Display respectively: Current pack voltage, Max. Pack
voltage, Min. Pack voltage, Pack voltage difference. (▣P =

HV-LV

)


Data Holding

When in Voltage Monitor status, press <▼> button for 3 seconds, after it shows ‖Start holding…‖, the
calculagraph will be shown alternatively at the upper right corner of the LCD screen.
Press <▼> for 3 seconds again, the screen will show ‖Stop holding!‖ and then exit.

View holding Point

In the monitor status, press <▲> and <▼> at the same time to enter the view logging point status.
Three points voltage data can be searched:‖Starting holding…‖data, ‖Stop holding!‖ data, and the data of
voltage alarm during this period , which can be shifted by < > buttons. Press < > for 3 seconds,it will return
to the monitor status.
The saved data can be covered till next logging.
If the logging time is over the users setting safety time,(See Monitor Safety Time Setting in P11), it will
trigger Safety Time Alarm, and the screen shows ‖T_OVER‖ alternatively in the upper right corner.

Alarm configuration Name

Notes

1234567-

7S

28.79

6H

4.162

1L

4.013

V

149mV

Pack Voltage

The highest voltage
The lowest voltage
The maximum
voltage difference

Cell Number

Voltage

Histogram

1

4.013V

2

4.150V

3

4.110V

4

4.152V

5

4.087V

6

4.162V

7

4.120V

8

------

Cell Voltage

Cell Number

7S

28.79V

V

149mV

1

4.01

2

4.15

3

4.11

4

4.15

5

4.08

6

4.16

7

4.12

8

----

Pack Voltage

The Max. Voltage
difference

Cell Number

Cell Voltage

7S

28.79V

HV

28.80V

LV

28.78V

P

0.020V

Pack Voltage
Max. Pack Voltage
Min. Pack Voltage

Pack Voltage Difference

<▢>

<>

<▢>

<>

<▢>

<>