6

I/O Module Installation Manual

2.9

Fuse Replacement

Use the following steps to replace fuses in the

I/O

Module

. See Figure 2-1 on page 2 for fuse locations.

To protect against the risk of fire, only
replace fuses with same type and rating
(see Section 4.1 on page 10
for proper
fuse types and ratings).

1. Disconnect power to the

I/O Module

.

2. Place

I/O Module

on an antistatic work mat.

Loosen the clamps of the enclosure body, then
open the

I/O Module

(see Figure 2-6 on page

8).

3. Remove fuse(s) from holders on power

supply bracket and replace with new fuse(s) –
(RLWS PN 80869).

4. Replace cover on enclosure and torque

clamps until they bottom out and gasket fully
compresses to maintain NEMA 4X integrity.

2.10 I/O Module Mounting

The

I/O Module

is capable of being mounted to any

surface in the safe area using the mounting holes of
the enclosure (see Figure 2-5 on page 7). Use 1/4" or
larger mounting hardware.

NOTE:

Mounting surface must be capable of holding

four times the weight of the

I/O Module

and wiring.

2.11 Battery Replacement

The lithium battery on the

I/O Module

board maintains

the real–time clock and protects data stored in the
system RAM when it is not connected to AC power.

Data protected by the

I/O Module

board battery

includes time and date.

Use

Revolution III

to store a copy of the indicator

configuration on a PC before attempting battery
replacem ent. If an y d ata is lost, the in dicator
configuration can be restored from the PC.

Watch for the

LOWBAT

warning on the LED display

and periodically check the battery voltage of your

320IS/320IS Plus

. batteries should be replaced when

the indicator low battery warning comes on, or when
battery voltage falls to 2.2 VDC. Life expectancy of
the battery is seven years.

See Figure 2-1 on page 2 for battery board battery
location and orientation (positive side up).

Risk of explosion if battery is replaced with incorrect
t y p e . D i s p o s e o f b a t t e r i e s p e r m a n u f a c t u r e r
instruction.