Rice Lake 480 Panel Mount Option User Manual

Page 3

Advertising
background image

480 Legend Series Panel Mount Option

3

12. Tighten the center screw of the clamp assembly until the indicator is pressed securely against the inner

bezel gasket.

Figure 5. Tighten Clamp Assembly

13. Tighten the outer screws of both clamp assemblies until the front bezel is held securely against the front

surface of the panel.

To Perform Maintenance on the 480 Legend Series Indicator

1. Loosen the outer screws on one clamp assembly to relieve pressure on the center screw.

2. Loosen the center screw so that the clamp assembly can be pulled out of the way of the back panel of the

indicator. There is no need to completely remove the clamp assembly.

3. Remove the back panel of the indicator and perform the required maintenance as indicated by the 480

Legend Series manual.

4. Tighten the center screw of the clamp assembly, engaging the clamp bar in the bezel bracket as shown,

until the indicator is pressed securely against the inner bezel gasket.

5. Tighten the outer screws of the clamp assembly until the front bezel is held securely against the front

surface of the panel.

See the

480 Legend Series Installation Manual, PN 119201

, for more information about installation procedures and

requirements.

Advertising