Note

3

520 Indicator Operator Card

If the checkweigh function is enabled,

setpoints remain configured but do not

function until checkweigh is disabled.

Some indicator configurations may not allow

checkweigh values to be changed through the

front panel or may require a password to

display or change the checkweigh value.

2.1.12

Set Date

In front panel setup mode use the arrow keys to toggle

to

Date

. Press

DOWN

or

ENTER

to enter the date in the

format configured for the indicator: MMDDYY,

DDMMYY, or YYMMDD.

2.1.13

Set Time

In front panel setup mode use the arrow keys to toggle

to

Time

. Press

DOWN

or

ENTER

to enter the time in

24-hour format, then press the

ENTER

key.

2.1.14

Display Accumulator

The accumulator must be enabled before use in either

normal mode or setpoint operations. Once enabled,

weight (net weight if a tare is in the system) is

accumulated whenever a print operation is performed

using the

PRINT

key, digital input, or serial command.

The scale must return to zero (net zero if a tare is in the

system) before the next accumulation.

1. Press and hold the

G/N

key for three seconds to

display the accumulated value if accumulator

is enabled.

2. Press the

UP

key to clear the accumulator or

the

PRINT

key to print the accumulator.

Note

The

PRINT

key only performs one

accumulation. Weight must return to zero
before another accumulation is allowed.

2.1.15

Count Display Mode

Count mode is entered by pressing the

MODE

(GROSS/NET) key from normal weighing mode when

count mode is enabled. In count display mode, the

display shows the number of parts rather than weight.

The annunciator at the right side of the LCD display

reads piece count (PC). Pressing the

PRINT

key sends

the CFMT print format data string to the serial port.
If a sample weight has not yet been acquired, the

indicator switches automatically to sample acquisition

mode.

2.1.16

Peak Hold Mode

The peak hold function is used to determine, display,

and print the greatest net weight read during a

weighing cycle.

A weighing cycle ends when the print command is

given, or when the peak net weight is manually cleared

by the

ZERO

key. Peak hold tracks only net weight and

operates independently of the display. For example, if

the indicator is displaying gross weight, but AUTO

peak hold is active, the display remains in gross, but

the net peak weight is automatically printed when

standstill is achieved at net zero.
Peak hold function is enabled in the setup mode.

Parameter settings are found under the PK HOLD

submenu, in first level program menu.

Note

Setpoint, time and date, and checkweigh value
changes from weigh mode (press and hold the

UNITS

key), accumulator display (press and

hold the

G/N

key), keyed tare display (press and hold the

TARE

key), and password entry front panel entry modes

timeout after 10 seconds if there is no activity.