2 installing devicenet option in the 520, Installing devicenet option in the 520, Devicenet module – Rice Lake 920i Programmable HMI Indicator/Controller - DeviceNet Interface User Manual

Page 7: W arning

Advertising
background image

Installation

3

9. Ensure no excess cable is left inside the

enclosure and tighten cord grips.

10. Reconnect power to the indicator. The

i n d i c a t o r a u t o m a t i c a l l y r e c o g n i z e s a l l
installed option cards when the unit is
p o w e r e d o n . N o h a r d w a r e - s p e c i f i c
configuration is required to identify the
newly-installed DeviceNet Interface to the
system.

Figure 2-4. Bus Adapter Card and DeviceNet Module

2.1.2

Installing DeviceNet Option in the 520

Use the following procedure to install the DeviceNet
Interface in the

520

indicator:

1. Disconnect indicator from power source.

Disconnect power before removing
indicator enclosure cover.

The

520

has no on/off switch. Before

opening the unit, ensure the power cord is
disconnected from the power outlet.

2. Place indicator on an antistatic work mat.

Remove screws that hold the enclosure cover
to the enclosure body.

Use a wrist strap to ground yourself and
protect components from electrostatic
discharge (ESD) when working inside the
indicator enclosure.

3. Carefully align the large option card

connector with connector J2 on the CPU
board (see Figure 2-5). Press

down

to seat the

option card in the CPU board connector.

Figure 2-5. Option Installed on

520 CPU Board

4. Use screws provided in the option kit to

secure the other end of the option card to the
threaded standoffs on the CPU board.

5. Install terminal block end of cable assembly

to DeviceNet option card.

6. Remove existing cover plate.

7. Re-use kep nuts to secure DeviceNet cover

plate to sta ndo ffs loca te d o n in side of
enclosure backplate (see Figure 2-6).

8. Once cabling is complete, position the cover

over the enclosure and reinstall the screws.

9. Reconnect power to the indicator.

Figure 2-6. DeviceNet Cable Assembly

10. The indicator automatically recognizes all

installed option cards when the unit is
p o w e r e d o n . N o h a r d w a r e - s p e c i f i c
configuration is required to identify the
newly-installed DeviceNet interface to the
system.

J2

TEST

3.3V

GND

J1

V+

V–

CAN_L

CAN_H

SHIELD

DeviceNet

Module

LED Array

DIP Switch

W arning

Cover Plate

Standoffs

Advertising